VenturiOne® FAQ’s
The Plot Format tab is only displayed when a plot is selected in the Plots area. The Region Format tab is only displayed when a region is selected on a plot displayed in the Plots area.
Click the Increase Preview Plot Size button (Preview tab) to magnify all the plots displayed in the Previews area.
Change the scaling of the plots to optimally display the events population. Select either Linear, Logarithmic or V-log from the Preview tab.
V-Log is an axis transformation that is similar to Logarithmic for the upper three decades, but has a Linear section around the axis. It allows visualization of low intensity fluorescence and improves visualization of compensated data particularly if overcompensation occurs.
If a gate equation contains more than 23 Boolean operands (i.e. regions), the system may slow down significantly. We recommend that you limit the number of operands to 23.
Compensation values are only displayed on the dual parameter plots that are displayed in the Previews area. Only Fluorescence parameters can be compensated. Scatter parameters cannot be compensated, therefore scatter parameters plots will not have compensation values displayed.
Ensure that the Manual Compensation option (Compensation tab) is selected; also note that the Manual Compensationoption will not be available for FCS2.0 10bit files which cannot be compensated.
A compensation matrix can only be calculated accurately when Log or V-Log scaling is selected, we do not recommend using Linear scaling when calculating a compensation matrix.
Fluorescence compensation settings that are applied to a Workspace can be saved as a compensation file and applied to other compensatable files.
After the software calculates the compensation coefficients for a single-stained file, values that do not require any compensation (i.e. represented as 0%)will still appear grey even though they have been calculated.
If the parameters in a file to be opened do not match those selected in the current Plots area, a Parameter Resolver is displayed. This enables the matching of the parameters so the new file can be opened in the current workspace.
Plots, regions, gates, color precedence, selected statistics and displayed parameters are included in a VenturiOne® Workspace.
The region label must fit within the boundaries of the plot space. Ensure that the region name is within these limits and that the associated statistic is displayed with the minimal number of decimal places.
Check that the designated region colour is not white. A white region and text will be hidden by the white plot background.
Check that the color white is not selected as a color precedence option. The white population will be hidden by the white plot background.
Check that black is not selected as a colour precedence option. Alternatively, ensure that the relevant gate is checked in the Precedence Order dialog.
Hover the cursor over the intercept of a Quadrant to display a tool tip displaying the region names and associated statistics.
Single and multiple vertical re-entrants can be created.
The Region Position button can only be used to modify the position of a created Elliptical, Rectangular, Linear or Quadrant regions.
Region names can be repositioned by selecting a region and dragging the name to a new position, as indicated by the cursor.
A Snapshot cannot be taken of a DNA Cell Cycle plot. The New Snapshot button is enabled when one or more histograms are displayed in the Plots area, however if one of the histograms is a DNA Cell Cycle plot, Snapshots will only be taken of the Histograms. To generate a Snapshot of the DNA plot it must be converted to a Histogram by selecting the plot and clicking the Histogram button, positioned on the Plot type group (Plot Format tab).
Select the region and click the Automatic Region Name Position button (Region Format tab). The associated region name will return to its default position.
The DNA Statistics group options are only enabled when the Results tab is selected. The DNA statistics cannot be displayed on the plots.
To export and paste the plots displayed in the Hierarchy format, ALL the Parent and Child plots must be selected to maintain the format. If all the plots are not selected, only those plots that are selected will be copied and when pasted they will be displayed in the Gallery format.
Plots involved in the Hierarchy are arranged in alphabetical order according to the name of the gate applied. Therefore, if a gate name is changes the plots involved in the Hierarchy may be rearranged but the representation is not altered.
Regions on multiple plots can only be tracked if the regions are displayed on same parameter plots.
ChartJunk are the details displayed on the exported images; Background Shading, Regions, Gate Names, Region Labels, Axis Labels, Plot Frame and Axes Tickmarks.
If all the column headers are un-checked, it is not possible to right click on a column header to display the pop-up menu. To return this functionality, check a statistic check box (e.g. Count) positioned in the Statistics tab. The statistic is then displayed in the table. Right click on this column header to display the pop-up menu (refer to section 3.9.7 of the Operation Manual).
IDouble click the column separator for the hidden column to optimally visualize the column data.
If the entered Gate Equation exceeds the limits of the dialog box, click the button (Edit Gates dialog) to display a larger Gate Equation dialog box. Type the gate equation in this box (refer to section 3.5.6.1 of the Operation Manual).
The color theme is only modified in VenturiOne when using Windows Vista.
We recommend a 64-bit processor as this will improve the performance of the software. However, the technology of VenturiOne allows it to optimize the performance of the processing ability available and a 32-bit processor will be sufficient.
Yes if it is running Microsoft Windows Vista or XP operating systems.
The maximum guaranteed file size is 10 million events with 15 parameters.
There is no theoretical maximum file size that the software can handle; it will depend upon the memory and capability of the PC.
When you request a new license key from Applied Cytometry you must ensure the file that you email to us is generated on the same computer that you propose to install VenturiOne on, otherwise you will not be able to open the software.
To speak to one of our team email customersupport@appliedcytometry.com or telephone +44 (0)1909 547210. Alternatively, please complete the form on the Contact page and one of our team will contact you as soon as possible.
Get In TouchNecessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.